Handing over
New installation
Handing over
- Go through the plant together with the customers representative
- Instruct the users of the machinery
- Flush pipes before pump station is connected to remove impurities
- Install pump station and connect water, air and electricity
- Check connections to pump
Has to be checked by the local plumber and electrician
- Water inlet (pipe size, union, ball valve)
- Water outlet (pipe size, union, ball valve)
- Air inlet (pipe size, union, ball valve)
- Electricity (cable dimension, pre-fuse, circuit breaker)